In order to bring you the best possible user experience, this site uses Javascript. If you are seeing this message, it is likely that the Javascript option in your browser is disabled. For optimal viewing of this site, please ensure that Javascript is enabled for your browser.
Did you know that your browser is out of date? To get the best experience using our website we recommend that you upgrade to a newer version. Learn more.

SCOFF trial confirms that fasting is not needed before cath lab procedures

Interventional Cardiology and Cardiovascular Surgery

Key take-aways 

  • Complications were not increased if patients ate normally before minimally invasive heart procedures under sedation. 
  • Patient satisfaction was higher without fasting than with fasting. 
  • Together with the existing body of evidence, these results support reconsidering guideline recommendations to fast before cardiac catheterisation procedures. 

London, United Kingdom – 1 September 2024: There was no difference in complications in patients who fasted or did not fast before cardiac catheterisation procedures requiring conscious sedation, according to late-breaking research presented in a Hot Line session today at ESC Congress 2024.1 

“Fasting before a cardiac catheterisation procedure has been recommended to reduce the risk of inhaling the stomach contents and developing aspiration pneumonia. However, for procedures in the catheterisation lab, fasting may not reduce aspiration risk and there are downsides, such as patient discomfort, water depletion, poor blood sugar control and unnecessary fasting for delayed/cancelled procedures. In the SCOFF trial, we were able to show no increased risk of complications with normal eating and that is good news for patients and for healthcare professionals,” said Principal Investigator, Dr. David Ferreira of the John Hunter Hospital, Newcastle, Australia. 

The investigator-initiated, randomised SCOFF trial, with a prospective open-label, blinded endpoint design, assessed the non-inferiority of no fasting prior to cardiac catheterisation laboratory procedures requiring conscious sedation. Patients who had been referred for coronary angiography, coronary intervention or cardiac implantable electronic device-related procedures were recruited. They were randomised 1:1 to fasting before the procedure (no solid food for 6 hours and no clear liquids for 2 hours) or to no fasting where the patient was encouraged to have regular meals as usual, but this was not mandatory. 

The primary composite endpoint was hypotension, aspiration pneumonia, hyperglycaemia and hypoglycaemia assessed with a Bayesian approach. Secondary endpoints included contrast-induced nephropathy, new intensive care admissions post-procedure, new ventilation requirements post-procedure, new intensive care unit admissions, 30-day readmissions, 30-day mortality, 30-day pneumonia and pre-procedure patient satisfaction. 

In total, 716 patients were recruited from six sites in New South Wales, Australia. The mean age was 69 years and 35% were female. As expected, fasting times were longer with fasting compared with no fasting (solid fasting 13.2 hours vs. 3.0 hours, clear liquid fasting 7.0 hours vs. 2.4 hours). 

The primary composite outcome occurred in 19.1% in the fasting group and 12.0% in the no-fasting group. In an intention to treat analysis, the estimate of the mean posterior difference was −5.2% (95% confidence interval [CI] −9.6 to −0.9) favouring no fasting. This result confirmed the non-inferiority of no fasting, based on a non-inferiority margin of 3% with a likelihood of greater than 99.5%. No fasting was also potentially superior to fasting for the primary outcome with a likelihood of 99.1%. There was an absolute risk difference between the groups of 7.1% in favour of no fasting, with a number needed to treat of 14.1 to prevent one primary outcome event.  

In analyses of secondary outcome events, no apparent differences were observed without and with fasting. Patient satisfaction was significantly better without fasting vs. with fasting when assessed via a questionnaire: 11 vs. 15 points where a lower score indicates greater satisfaction (posterior mean difference, 4.02 points; 95% CI 3.36 to 4.67; Bayes factor ≥100). 

“Taken together with data from the CHOW-NOW,2 TONIC3 and the Fast-CIED4 trials and from various observational studies, there is now a strong case that fasting is not needed in patients undergoing these types of procedures. Removing fasting has been consistently shown to be safe, patients often prefer not to fast and there are logistical benefits to the healthcare system if patients can eat and drink normally. With this new evidence, I think it is now time to reconsider fasting requirements in clinical guidelines,” concluded Dr. Ferreira. 

ENDS 

Notes to editor

This press release accompanies both a presentation and an ESC press conference at ESC Congress 2024. It does not necessarily reflect the opinion of the European Society of Cardiology. 

 

ESC Press Office
Tel: +33 (0)6 61 40 18 84 
Email: press@escardio.org

The hashtag for ESC Congress 2024 is #ESCCongress 

Follow us on X @ESCardioNews  

Journalists are invited to become accredited and register here

Check out the ESC Media and Embargo Policy

 

Funding: Funding for statistical analysis was from the John Hunter Hospital Charitable Trust and the Hunter Medical Research Institute Medical Research Support Program. 

Disclosures: No disclosures to report. 

 

References and notes 

1‘SCOFF - Fasting or no fasting before cardiac catheterisation procedures’ will be discussed during Hot Line 8 on Sunday 1 September in room London. 

2Mishra A. Strict versus no fasting prior to cardiac catheterization: a prospective evaluation of safety and clinical outcomes. Can we safely have our patients eat with cardiac catheterization – nix or allow: the CHOW NOW study [abstract 11758]. SCAI 2020 Virtual Scientific Sessions: Virtual Conference, May 14 to 16, 2020. 

3Boukantar M, Chiaroni P-M, Gallet R, et al. A randomized controlled trial of non-fasting vs fasting before interventional coronary procedures: the TONIC trial. JACC Cardiovasc Interv. 2024;17:1200–1210. 

4Bode K, Gerhards M, Doering M, et al. A randomized trial of non-fasting vs. fasting for cardiac implantable electronic device procedures (Fast-CIED Study). Europace. 2022;24:1617–1626. 

 

About ESC Congress 2024 

It is the world’s largest gathering of cardiovascular professionals, disseminating ground-breaking science both onsite in London and online – from 30 August to 2 September. Explore the scientific programme. More information is available from the ESC Press Office at press@escardio.org. 

About the European Society of Cardiology

The ESC brings together health care professionals from more than 150 countries, working to advance cardiovascular medicine and help people to live longer, healthier lives.