Rapid blood vessel scan tolerated by claustrophobic patients unable to stand longer tests

Embargo: 3 February 2018 at 10:15 CET

Cardiac Magnetic Resonance

Barcelona, Spain – 3 February 2018: Doctors have developed a new five-minute procedure to scan the blood vessels which offers hope for claustrophobic patients unable to tolerate the conventional longer test. The research is presented today at CMR 2018.1

Magnetic resonance angiography (MRA) is a magnetic resonance imaging (MRI) exam that takes pictures of the blood vessels. Physicians use the images to diagnose diseases of the blood vessels, such as aneurysms or blockages.

During the test patients lie on a table inside a tunnel-like tube and must remain still. A dye, called a contrast agent, is injected into the veins so the vessels can be seen more clearly. Patients are given a headset to block out noise from the scanner.  An MRA can typically take 30 minutes to one hour, from start to finish.

“Lengthy scans can be problematic for patients with even modest levels of claustrophobia who may refuse the test or ask for it to be stopped early,” said Dr Puja Shahrouki, research fellow, David Geffen School of Medicine at UCLA, Los Angeles, US. “They also limit the number of patients that can be scanned each day. In addition, the usual gadolinium-based contrast agents can be an issue for patients with kidney problems.”

This study aimed to shorten the scan time and still produce high quality images. The researchers used ferumoxytol as the contrast agent as it stays within the vascular system for much longer than gadolinium-based dyes. With gadolinium-based agents, there is a short time when the images can be taken, which means patients have to wait in the scanner while the clinician watches the dye move through the body in order to capture the images when the dye enters the blood vessels.

The UCLA study included seven claustrophobic patients aged 11 to 63 years with kidney failure. There were four men and three women. All patients said they were reluctant to undergo MRA due to claustrophobia, but agreed to a trial of up to ten minutes in the scanner bore.

Eight MRA scans using ferumoxytol were conducted. All scans were completed and there were no adverse events. Scans took an average of 6.27 minutes (range four to ten minutes). All scans were high quality and allowed full visualisation of the arterial and venous anatomy from the neck to the thighs (see photo).

“Despite being claustrophobic, all patients completed the MRA and the images could be used for diagnosis of the entire vascular system,” said Dr Shahrouki. “Some of the scans were done in less than five minutes once the procedure started, making it much shorter than the tests currently used in medical practice.”

The researchers have shown that the test can be used to diagnose venous and arterial diseases, such as central venous occlusion and aneurysms, and to aid preprocedural planning, for example in transcatheter aortic valve replacement. In principle, it is possible to scan several patients in an hour as opposed to just one or two, raising promising possibilities for workflow and efficiency.

Dr Shahrouki said: “This method could enable claustrophobic patients to receive lifesaving diagnoses and procedures. For appropriate types of studies, it could also shorten waiting lists and improve the cost-benefit ratio for hospitals.”

The new protocol should be technically easier than current practice because there is no time pressure for taking images. Ferumoxytol is increasingly recognised as an alternate contrast agent in patients with poor kidney function, but is not marketed outside the US. It is approved by the US Food and Drug Administration (FDA) only for the treatment of iron deficiency anaemia in adults with chronic kidney disease.

Hypersensitivity reactions have occurred in patients receiving ferumoxytol as a high dose for therapy in a short period of time, and the FDA has warned against this.  The new MRA protocol administers the dye by slow infusion outside the MRI machine while monitoring the patient’s vital signs, in compliance with FDA guidelines. A preliminary study showed this was safe2 and a larger registry is generating a safety profile of slow infusion under close monitoring. More safety data will be needed before any conclusions can be drawn about the true rate of hypersensitivity reactions and in the meantime close monitoring is the rule.

Dr Shahrouki said: “The protocol could have huge implications for claustrophobic patients and efficient use of scanners. We envisage it being used very widely in patients with a clear clinical indication.”

MRI-angiography-CMR-2018.jpg

Photo: Three dimensional images from magnetic resonance angiography with ferumoxytol in a claustrophobic 35 year-old female with a scanning time of 6 minutes and 57 seconds.

Photo credit: Dr Paul Finn

ENDS

Notes to editor

ESC Press Office
Tel: +33 (0) 4 89 87 24 83
Email: press@escardio.org

SOURCES OF FUNDING: None.

DISCLOSURES: None.

References and notes

1The abstract ‘Focused, Whole Body Vascular MR Imaging in Less than Five Minutes with Ferumoxytol’ will be presented during Poster Session 3 on 3 February 2018 at 10:15 to 11:00 CET.

2Nguyen KL, Yoshida T, Han F, Ayad I, Reemtsen BL, Salusky IB, Satou GM, Hu P, Finn JP. MRI with ferumoxytol: A single center experience of safety across the age spectrum. J Magn Reson Imaging. 2017;45(3):804–812. doi: 10.1002/jmri.25412.

About CMR 2018

CMR 2018 is a joint EuroCMR and SCMR meeting organised by the European Association of Cardiovascular Imaging (EACVI), a registered branch of the European Society of Cardiology, and the Society for Cardiovascular Magnetic Resonance (SCMR).

About the European Association of Cardiovascular Imaging (EACVI)

The European Association of Cardiovascular Imaging (EACVI) - a registered branch of the ESC - is the world leading network of Cardiovascular Imaging (CVI) experts, gathering four imaging modalities under one entity (Echocardiography, Cardiovascular Magnetic Resonance, Nuclear Cardiology and Cardiac Computed Tomography).

Its aim is to promote excellence in clinical diagnosis, research, technical development, and education in cardiovascular imaging.

The EACVI welcomes almost 10 000 professionals including cardiologists, sonographers, nurses, basic scientists and allied professionals.

About the European Society of Cardiology

The ESC brings together health care professionals from more than 150 countries, working to advance cardiovascular medicine and help people to live longer, healthier lives.

About the Society for Cardiovascular Magnetic Resonance (SCMR)

The mission of the Society for Cardiovascular Magnetic Resonance (SCMR) is to improve cardiovascular health by advancing the field of CMR. This is accomplished through education, advocacy, networking, research and clinical excellence.

Information for journalists attending CMR 2018

CMR 2018 takes place 31 January to 3 February in Barcelona, Spain, at the Centre Convencions Internacional de Barcelona (CCIB). The scientific programme is available here

Journalists wishing to attend CMR 2018 should email cmr2018@barcelocongresos.com